Skip to content
Greg Traver Construction

Why Is There Mold on My Bathroom Ceiling?

By Greg Traver, licensed general contractor (CA #839269) · · 4 min read

You scrub the dark spots off the ceiling above the shower. A few weeks later they're back. Bleach, mold-killing paint, a new coat of paint: the spots keep returning.

When that happens, the spots aren't the problem. They're a sign that moisture is staying in the room, or in the ceiling, long after the shower is off. Until that changes, they'll keep coming back.

Where the moisture comes from

A hot shower puts a lot of water vapor into the air. When that warm, wet air hits a cooler surface (the ceiling, an outside wall, a window), it condenses into droplets. A ceiling that stays damp for hours every day is exactly where mold likes to grow.

The fix is getting that moist air out of the house quickly. That's the job of the exhaust fan, and in a lot of older homes, the fan isn't doing it.

Common causes in older San Diego homes

No fan, or a fan that's too small

Many older bathrooms were built with only a window. In winter nobody opens it. And older fans are often undersized or so worn out they barely move air. A common rule of thumb is about 1 CFM (cubic foot per minute) of fan capacity for each square foot of bathroom floor.

The fan vents into the attic

This one is very common. The fan is there and it runs, but the duct ends in the attic instead of going outside, or it was never connected at all. The steam goes into the attic and condenses on the underside of the roof deck and on the insulation, sometimes right above the bathroom ceiling. Current building codes require bathroom fans to exhaust to the outside.

An uninsulated duct through a cold attic

Even when the duct does go outside, a bare metal or thin flexible duct running through a cool attic gets cold. Warm, wet air from the shower condenses inside the duct, and that water runs back down into the fan and drips onto, or soaks into, the drywall around it. Long, sagging duct runs make it worse because water collects in the low spots.

Missing or thin attic insulation over the bathroom

If the ceiling above the shower isn't well insulated, the drywall stays cooler than the rest of the room, so that's where condensation forms first. Spots that are worse in winter, or that follow the lines of ceiling joists, point to this.

Running the fan for too short a time

Turning the fan off when you step out leaves most of the moisture behind. Running it about 20 minutes after a shower, or putting it on a timer or humidity-sensing switch, makes a real difference.

How to tell surface spots from a bigger problem

  • Surface spots that wipe off and come back slowly are usually condensation on the paint. Fixing the ventilation is usually what stops them.
  • Stains, bubbling paint, sagging or soft drywall mean water is getting into the ceiling, from condensation in the attic, a dripping duct, or a leak from above.
  • A musty smell that doesn't go away, or growth that keeps spreading, is a reason to have it looked at by someone who can check inside the ceiling.

We're not going to tell you whether a particular mold is a health concern; that's a question for a qualified professional. The EPA's general guidance is that areas larger than about 10 square feet are a job for a professional rather than a sponge.

Greg doesn't do mold remediation. A remediation company handles the removal, drying and clearance; once the area is cleared, Greg handles the removal and replacement: new drywall, ceiling, paint, and fixing the ventilation so it doesn't come back.

What actually fixes it

Cleaning the spots treats the symptom. Lasting fixes deal with the moisture, and in most bathrooms that starts with the fan. Here's how Greg sets one up:

  • More than adequate CFM. He sizes the fan with capacity to spare rather than the bare minimum for the room.
  • A humidity-sensing fan. Greg prefers the type with a built-in moisture sensor, so it keeps running until the steam is actually gone instead of shutting off when you leave.
  • Always ducted to the outside, through the roof or the wall, whichever makes the most sense for that house. Never into the attic.
  • Close to the shower, where the steam is. In a large bathroom, it's not a bad idea to have two fans.

The rest of the fix:

  • A short, straight insulated duct that slopes slightly toward the outside so condensation can't run back to the fan.
  • Insulation over the bathroom ceiling.
  • Replacing drywall that has been wet, rather than painting over it, and using a moisture-resistant board and a bathroom-rated paint.

If you're planning a bathroom remodel anyway, it's the cheapest time to fix the ventilation, because the ceiling and walls are already open. And if the spots are concentrated around the shower itself, it may be a tile or waterproofing issue; see re-tile or remodel.

Send a photo of the ceiling and the fan grille and Greg can tell you what he'd look at first.